Relay1.pngPCB relay for robot battery isolation and actuator control

Product Overview

Relays are electrically controlled switching devices usedto connect, disconnect or redirect power and signal circuits. Anelectromagnetic relay uses a low-power coil signal to operate mechanicalcontacts, allowing a control circuit to safely switch a separate higher-voltageor higher-current load.

In robotic systems, relays are commonly used for main powerisolation, emergency shutdown, actuator control, auxiliary-load switching andsubsystem power management.

Key Functions

  • Connects and disconnects     electrical loads

  • Provides electrical     isolation between control and load circuits

  • Switches higher current     using a low-power control signal

  • Controls robot subsystem     power

  • Supports emergency     shutdown circuits

  • Isolates batteries     during storage, maintenance or fault conditions

  • Switches pumps, fans,     brakes, lights and auxiliary actuators

  • Provides normally open,     normally closed or changeover operation

  • Supports power     sequencing and fault recovery

  • Reduces standby power     consumption by disconnecting inactive loads

Typical Applications

  • Humanoid robots

  • Industrial robots and     cobots

  • AGVs and autonomous     mobile robots

  • Robot battery and     power-distribution systems

  • Emergency-stop circuits

  • Motor brake and solenoid     control

  • Pumps, fans and valves

  • Auxiliary lighting and     heating systems

  • Charging and docking     systems

  • Safety-interlock     circuits

  • Test and maintenance     equipment

Main Parts Inside the Relay

Electromagnetic Coil

The copper-wound coil generates a magnetic field whenenergized by the relay-driver circuit.

Iron Core

The core concentrates the coil’s magnetic field andincreases the force applied to the armature.

Movable Armature

The armature moves when attracted by the energizedelectromagnet, mechanically changing the contact position.

Return Spring

The spring returns the armature and contacts to theirdefault position when coil power is removed.

Switching Contacts

The contacts open or close the load circuit. Contactmaterials are selected according to voltage, current, switching frequency andexpected operating life.

Relay Terminals

The terminals connect the coil and switching contacts tothe PCB. PCB power relays commonly use through-hole terminals for mechanicalstrength and current capacity.

Sealed Housing

The housing protects the coil and contacts from dust,moisture and mechanical damage.

Contact Configurations

Configuration

Function

Normally Open—NO

The load is disconnected until  the coil is energized

Normally Closed—NC

The load remains connected  until the coil is energized

Changeover—COM/NO/NC

Switches the common terminal  between two contacts

SPST

Controls one independent  circuit

SPDT

Switches one common terminal  between two circuits

DPDT

Simultaneously switches two  independent circuits

Main Components on the Relay PCB

Relay

The relay provides mechanical switching and galvanicisolation between the low-power controller and the switched load.

Relay-Driver Transistor or MOSFET

The MCU normally cannot supply enough current to energizethe relay coil directly. A transistor or MOSFET amplifies the control signaland switches the coil current.

Flyback Diode

When the coil is switched off, it produces areverse-voltage spike. The flyback diode suppresses this spike and protects thedriver circuit.

Microcontroller

The MCU receives commands or safety signals and determineswhen each relay should open or close.

Fuse

The fuse interrupts the circuit when excessive current or ashort circuit occurs.

TVS Diode

The TVS diode suppresses transient voltage generated bycables, motors and other inductive loads.

Current-Sense Resistor and Amplifier

These components measure load current and help detectoverloads, short circuits or abnormal operating conditions.

Voltage Supervisor

Monitors the power supply and prevents unstable relayoperation during undervoltage or startup conditions.

CAN Transceiver

Connects the relay-control board to the robot’s maincontroller for commands, status reporting and fault diagnostics.

Status Indicator

An LED may indicate whether the relay coil is energized. Itshould not be treated as confirmation that the mechanical contacts haveswitched successfully.

Power Connectors

High-current locking connectors connect the battery, loadand power-distribution wiring to the PCB.

Isolation Slot and Creepage Spacing

Physical separation between the control and load areashelps maintain electrical isolation and reduce the risk of arcing.

How It Works

The robot controller sends a switching command to therelay-control PCB. A transistor or MOSFET energizes the relay coil, creating amagnetic field that moves the armature and changes the contact state.

The contacts then connect or disconnect the battery,actuator or auxiliary load. When the coil is turned off, the return springrestores the contacts to their default position.

Typical Control Flow

Robot Controller → Relay Driver → RelayCoil → Mechanical Contacts → Electrical Load

Typical Power Flow

Battery → Fuse and Protection → RelayContacts → Power Distribution or Auxiliary Load

Common Relay Types

Relay   type

Typical   use

Electromagnetic Power Relay

PCB power switching and  electrical isolation

Signal Relay

Low-current control and  communication signals

Latching Relay

Maintains its state without  continuous coil power

Solid-State Relay

Silent, high-frequency  switching without mechanical contacts

Safety Relay

Monitored safety and  emergency-stop circuits

Automotive Relay

Battery-powered equipment and  vehicle-style systems

DC Contactor

High-voltage or high-current  battery isolation

Key Benefits

  • Galvanic isolation

  • Simple control interface    

  • High off-state isolation    

  • Supports AC or DC load     switching

  • Normally open and     normally closed options

  • Low leakage current when     contacts are open

  • Suitable for emergency     and maintenance isolation

  • Easy visual and     electrical troubleshooting

Selection Parameters

When selecting a relay, consider:

  • Coil voltage and coil     power

  • Contact configuration

  • Maximum switching     voltage

  • Continuous and peak     contact current

  • DC or AC load     characteristics

  • Resistive, capacitive or     inductive load type

  • Contact resistance

  • Electrical and     mechanical life

  • Switching and release     time

  • Isolation voltage

  • Operating-temperature     range

  • Package dimensions and     PCB footprint

  • Sealed or unsealed     construction

  • Vibration and shock     resistance

  • Latching or non-latching     operation

  • Industrial or automotive     qualification

Design Considerations

  • Inductive loads can     produce high voltage when switched off and require suppression.

  • Motor and capacitive     loads may have startup currents much higher than their normal operating     current.

  • A relay’s DC switching     capacity may be lower than its AC rating.

  • Relay contacts can wear,     bounce or weld if incorrectly selected.

  • A flyback diode must be     installed across a DC coil unless suppression is integrated.

  • High-current PCB paths     require suitable copper thickness, trace width and terminal design.

  • Safety-critical systems     may require contact-state feedback or mechanically guided contacts.

  • Standard PCB relays     should not automatically be treated as emergency-stop safety components.

Short Product Description

Antfieldrelay solutions provide reliable electrical isolation, power switching andsubsystem control for robotic platforms. Designed for battery isolation,emergency shutdown, actuator control and auxiliary-load management, our relaycomponents can be supported by customized PCB, PCBA and electronic-componentsourcing services.


Global Product Inquiry
Custom PCB Fabrication, PCBA Assembly & Component Procurement Solution
Inheriting the Ant Spirit, Building Core Competitiveness in Electronic Supply Chain with Professionalism & Dedication.
PRODUCT
CONTACT
+86-13902944251 judy@atftek.com