Product Overview

Connectors provide removable electrical and mechanicalconnections between robotic PCBs, sensors, controllers, motors, batteries andcommunication modules.

A complete wire-to-board connector system normally consistsof a PCB header, mating receptacle housing, crimp terminals and cable harness.Locking and polarization features help prevent accidental disconnection orincorrect mating in environments exposed to vibration and repeated movement.

Key Functions

  • Transfers power,     communication signals and sensor data

  • Connects cable harnesses     to PCBs

  • Supports removable     modules and field maintenance

  • Prevents incorrect     mating through polarized keying

  • Reduces accidental     disconnection through locking mechanisms

  • Provides reliable     contact under vibration and movement

  • Supports differential     communication signals

  • Simplifies robot     assembly and cable management

  • Enables modular     replacement of sensors and controllers

  • Supports compact,     high-density wiring

Typical Applications

  • Humanoid robots

  • Industrial robotic arms

  • AGVs and AMRs

  • Service and delivery     robots

  • Robot joint controllers

  • Vision and camera     modules

  • Encoders and Hall     sensors

  • Battery and     power-distribution systems

  • CAN and RS-485     communication networks

  • Motor drives and     actuators

  • Internal wiring     harnesses

Main Parts of a Connector System

PCB Header

The header is soldered onto the PCB and provides the fixedmating interface. Right-angle or vertical versions may be selected according toavailable installation space.

Receptacle Housing

The housing holds the crimp terminals, provides electricalinsulation and aligns the cable-side contacts with the PCB header.

Crimp Terminal

The metal terminal is mechanically crimped to the conductorand insulation. It creates the electrical connection between the wire andmating contact.

Positive-Lock Latch

The latch holds the two connector halves together andreduces the risk of disconnection caused by vibration, pulling or repeatedrobot movement.

Polarization and Keying

Mechanical ribs and asymmetric shapes prevent incorrectorientation or mating with an incompatible connector.

Contact Plating

Tin, gold or other plating materials protect the contactsurface and influence contact resistance, durability and corrosion resistance.

Strain Relief

The crimp wings, cable sleeve and external harness supportprevent pulling forces from being transferred directly to the electricalcontact.

Main Components on the Connectivity PCB

Connectors

Board headers connect power and communication harnesses tothe PCB. Mechanical hold-down tabs improve resistance to insertion and cableforces.

Microcontroller

The MCU manages communication, diagnostic information andinterface-control functions.

CAN Transceiver

Converts controller logic signals into the differentialelectrical signals used on a CAN bus.

RS-485 Transceiver

Provides robust differential communication for longer cabledistances and electrically noisy environments.

ESD/TVS Protection

Protection diodes suppress electrostatic discharge andcable-induced voltage transients before they reach sensitive ICs.

Common-Mode Choke

Reduces high-frequency common-mode noise on differentialcommunication lines.

Termination Resistors

Match the impedance of CAN or RS-485 networks and helpreduce signal reflections.

Ferrite Beads

Suppress high-frequency noise entering through power orsignal connections.

DC-DC Converter and LDO

Generate the regulated supply voltages required by the MCU,transceivers and interface circuits.

Resettable Fuse

Limits excessive current caused by cable faults orincorrectly connected external equipment.

Reverse-Polarity Protection

Protects the PCB if the power connection is reversed orincorrectly assembled.

Crystal Oscillator

Provides a stable clock reference for the controller andcommunication interfaces.

How It Works

Crimp terminals are attached to the individual wires andinserted into the receptacle housing. The receptacle is then plugged into thematching PCB header until the latch locks.

Power conductors deliver electrical energy, while twisteddifferential pairs transfer CAN or RS-485 communication signals. Thetransceiver, filtering and protection circuits condition the signals beforethey reach the MCU or other controller.

Typical Connection Flow

Robot Main Controller → CommunicationPCB → Connector → Cable Harness → Sensor or Joint Controller

Common Connector Types

Connector   type

Typical   robot application

Wire-to-Board Connector

Sensors, motors, power and  internal harnesses

Board-to-Board Connector

Stacked PCBs and computing  modules

FFC/FPC Connector

Cameras, displays and compact  sensor modules

Circular Connector

External equipment and harsh  environments

Coaxial Connector

Cameras, antennas and  high-frequency signals

Ethernet Connector

High-speed robot networking

USB Connector

Programming, diagnostics and  peripheral devices

Battery Connector

High-current battery and power  connections

Waterproof Connector

Outdoor, cleaning and  inspection robots

Selection Parameters

When selecting a connector, consider:

  • Number of contacts

  • Contact pitch

  • Rated voltage and current

  • Wire size or AWG range

  • Contact resistance

  • Insulation resistance

  • Mating-cycle requirement    

  • Locking and polarization     design

  • Vertical or right-angle     orientation

  • Through-hole or     surface-mount termination

  • Operating-temperature     range

  • Vibration and shock     resistance

  • IP or sealing     requirement

  • Shielding and EMC     performance

  • Creepage and clearance     distances

  • Flammability rating

  • Cable-bend and     installation space

  • Manual or automated     assembly method

Design Considerations

  • Use twisted pairs for     CAN, RS-485 and other differential signals.

  • Place ESD protection     close to the connector entry point.

  • Separate noisy     motor-power wiring from sensitive communication cables.

  • Provide strain relief     near moving joints.

  • Avoid routing cables     across sharp metal edges.

  • Maintain sufficient bend     radius and service-loop length.

  • Verify connector     retention under vibration and repeated motion.

  • Check both     connector-current rating and temperature rise.

  • Define crimp height,     pull-force and terminal-inspection requirements.

  • Confirm housing,     terminal and header part numbers as a compatible set.

Short Product Description

Antfieldconnector solutions provide reliable power, signal and communicationinterconnection for robotic PCBs, sensors, motor controllers and distributedcontrol systems. Locking, polarized and high-density connector options supportvibration resistance, modular assembly and efficient robot maintenance.


Global Product Inquiry
Custom PCB Fabrication, PCBA Assembly & Component Procurement Solution
Inheriting the Ant Spirit, Building Core Competitiveness in Electronic Supply Chain with Professionalism & Dedication.
PRODUCT
CONTACT
+86-13902944251 judy@atftek.com